Pluvio² L – Rain Gauge / Precipitation Gauge
- Regular price
- 9.999,00€
- Sale price
- 9.999,00€
- Regular price
-
Pluvio² L - Precipitation sensor based on the weighing principle for liquid, solid and mixed precipitation.
Attention: Due to the current delivery situation, please request the product by email or via our contact form!
The weighing rain gauge OTT Pluvio² L measures precisely and reliably in rain, sleet, hail or snow. Taking into account peripheral factors such as temperature and wind, it records both the amount and intensity of all precipitation and delivers accurate values even in light drizzle. Developed in collaboration with leading weather services, the OTT Pluvio² L rain gauge meets the highest standards. It is long-term stable and robust, requires only minimal maintenance and is characterized by comparatively low operating costs.
Technical data:
| General data | |
| types of precipitation | liquid, solid and mixed |
| collection area | 200 cm² / 400 cm² |
| collection volume | 1500 mm / 750 mm |
| sensor element | sealed load cell |
| interfaces | |
| USB | configuration/service mode and firmware update |
| Serial interfaces | SDI-12 or RS-485 |
| digital outputs | Pulse 0.1 mm (configurable) and status (0…120 pulses/min; configurable 5 or 2Hz) |
| measured value output | Intensity EZ Quantity EZ/NEZ, Quantity NEZ, Total NEZ, Container contents EZ and NEZ Temperature load cell, Status Pluvio² Status heating (if available) |
| Electrical and mechanical data | |
| power supply | 9.6...28VDC; Low power: 5.5...28 VDC |
| power consumption | typ. 12 mA at 12 V; Low Power: typ. 4.5 mA at 12 V |
| ring heater, optional | Pluvio2 200: 24 VDC / max. 50 watts; |
| Pluvio2 400: 24 VDC / max. 100 watts | |
| Dimensions (Ø xh) | |
| Pluvio² 200 / 400 | 450mm x 740mm / 450mm x 660mm |
| standpipe | (Ø) 110-120 mm ( 4 “) |
| Weight | (empty container) 15 kg |
| material | |
| base plate | stainless steel, aluminum |
| collection container | polyethylene |
| tubular housing | ASA, UV resistant |
| environmental conditions | |
| temperature, operation | -40 … +60 °C |
| temperature, storage | -50 … +70 °C |
| Relative humidity | 0 … 100% (not condensed) |
| Protection | |
| Housing | IP 54, salt mist resistant |
| load cell / electronics | IP 67 / IP 64 |
| EMC | EN 61000-4-2/4/5/6, Level 5 (4 kV) EM/EMI EN 61000-4-3, CE compliant |
| measuring ranges | |
| precipitation | 0…50 mm/min or 0…3000.00 mm/h |
| quantity threshold at 60min collection time | 0.05 mm/h |
| intensity threshold | 0.1 mm/h or 6 mm/h |
| resolution | |
| pulse output | 0.1 mm |
| SDI-12 and RS-485 | 0.01 mm/min, 0.01 mm/min or mm/h |
| accuracy | |
| (at -25°C … +45°C) | |
| Crowd | ± 0.1 mm or ±1% of measured value |
| intensity | ± 0.1 mm/min or ± 6 mm/h |
| times | |
| output interval intensity | 1 minute |
| output delay | EZ 18 seconds NEZ 5 minutes |
| query interval | 6 seconds .... 60 minutes |
| Further versions: | |
| S04436.1002 Pluvio² precipitation sensor based on weighing principle 200mm² collection area with heating | |
| S04436.2001 Pluvio² precipitation sensor based on weighing principle 400mm² collection area | |
| S04436.2002 Pluvio² precipitation sensor based on weighing principle 400mm² collection area with heating | |